Modbus RTU IO Module for Sale

Decowell has two series of Modbus RTU remote IO system, one is EX IO module and the other one is RB IO module, they both show excellent compatibility and reliability in industrial automation by virtue of stable RS485 serial communication.

They both support the standard Modbus RTU protocol, which can easily interface with various types of PLCs, HMIs and host systems; they have strong anti-jamming capability, which is suitable for complex electromagnetic environments; and they also support a variety of IO signal types, which can satisfy the diversified control needs of digital, analog, temperature, etc. The modules are compact in structure and support DIN rail. Compact module structure, support DIN rail mounting, easy system integration and space optimization, is the ideal choice for building efficient, economical and scalable control system.

Why need Modbus RTU IO modules?

In industrial automation system, data acquisition and signal output between field devices and control system are crucial. Modbus RTU IO module serves as a bridge, responsible for transmitting digital or analog signals from sensors, actuators and other field devices to PLC or host control system in a fast and stable way. Its RS485-based communication method supports serial connection of multiple devices with simple wiring and stable communication, which is especially suitable for industrial sites with high requirements for anti-interference capability, compact space and sensitive cost. Modbus RTU IO module is an indispensable key component for projects that require reliable data transmission and control between multiple devices.

Why do I need Modbus RTU IO modules

We offer a wide range of Modbus RTU IO modules and adapters covering different IO point combinations, communication methods and functional configurations. Whether you need to integrate a compact device or expand a large control system, we have the right product for you. For complete selection information, please refer to the selection brochure on the right or contact our online customer service for technical support.

EX-1030 – MODBUS-RTU Adapter Specifications
ParameterSpecification
Product modelEX-1030
Product nameMODBUS-RTU Adapter
Address setting0~99
CableMODBUS-RTU special cable
Transmission distance1200m (max)
Bus rateRS485 Baud rate optional: 1200, 2400, 4800, 9600, 19.2K, 28.8K, 38.4K, 57.6K, 115.2K
EX System power input24V (18 ~ 36V)
EX System provides current2A (Max)
IO port power supply input24V (±20%)
IO port current output10A (Max)
Expandable I/O channels32
Input/output maximum bytes512 bytes / 512 bytes
Dimensions90mm × 67mm × 34mm
Temperature rangeWorking temperature: 0 ~ 55°C
Storing temperature: -20 ~ +85°C
Relative humidity95% (No Condensation)
Protection gradeIP20

As a slave device, Modbus RTU IO module communicates with PLC, SCADA system, cloud platform or other master devices through RS485 interface to collect switching and analog signals to realize data acquisition and remote control functions, which is widely used in automation control, environment monitoring and equipment status management scenarios.

Application Architecture

Modbus RTU IO module is widely used in industrial automation control system by virtue of its stable RS485 communication method, strong anti-interference ability and rich IO configuration. Whether in the signal acquisition of mechanical equipment, intelligent monitoring of building control, or remote switching control of power system, it can provide reliable data transmission and flexible system expansion capability. Suitable for various centralized or distributed control architectures, it is the ideal choice for OEMs and system integrators.

Simplicity of Network Cabling

The Modbus RTU IO module communicates via RS485 serial bus with standard two-wire wiring and supports up to 32 slave devices to be connected, such as IO modules, sensors and so on. Simple wiring saves costs. Compared with the complex Ethernet wiring, RS485 structure is more suitable for long-distance transmission and anti-jamming communication in the industrial field, which is widely used in PLC control system, sensor network, building automation and other scenarios. No need for switches and other network equipment, debugging and maintenance is more convenient, is a cost-effective communication solution in industrial automation.

Simplicity of Network Cabling
anti-interference capability

High Anti-interference Capability

Modbus RTU IO modules have excellent electromagnetic compatibility (EMC), adopting industrial-grade design standards, effectively protecting against surge, electromagnetic interference, electrostatic discharge and other common sources of on-site interference, ensuring stable and reliable data communication. Especially in high voltage, high current, strong interference in electrical control cabinets, factory floors and other complex environments, can still ensure the continuous operation of the system. Combined with RS485 differential signal communication to further enhance anti-jamming performance, it is an ideal choice for highly reliable data acquisition and control in industrial automation scenarios.

Compact Design, Flexible Installation

One of the RB IO modules in the Modbus RTU Remote IO series is designed in a compact structure with a small footprint, which is especially suitable for applications with limited space inside the control cabinet. Supporting standard DIN rail mounting, it can be quickly deployed without complicated operation, saving installation time and labor cost. Whether in centralized control systems or distributed IO applications, it enables rapid integration and flexible expansion.

Compact design, flexible installation

Related Products

To better meet your diverse needs in industrial automation, we also offer many types of automation equipment such as IO modules, PLC controllers, valve islands and industrial switches.

Explanation of Every Detail, Help You Easily Select and Apply

In the process of selecting and using Modbus RTU IO modules, you may be concerned about whether the communication methods are compatible, how to carry out network wiring, whether the module is easy to install, whether the parameters are easy to configure, and many other issues. In order to help you understand the products more efficiently, we have carefully organized FAQs covering protocol interface, product performance, system integration, installation and maintenance.

Whether you are an engineer who is new to this type of product or an experienced system integrator, these questions will provide you with practical information and support. If you encounter more personalized needs or problems in the actual application, please feel free to contact our pre-sales technical team, we will provide you with fast, professional response and service.

What is the maximum number of devices that can be connected to a Modbus RTU IO module?

Supports up to 32 nodes (both master and slave) on a standard RS485 bus. Expansion to more modules is possible if repeaters are used.

Does the module support multi-master access?

Modbus RTU is a master-slave communication structure, and there is usually only one master on a bus. If more than one master access is required, please use Modbus TCP module or consider realizing multi-master access through protocol conversion.

Is it compatible with mainstream PLC brands?

Yes. Our Modbus RTU IO modules follow the standard Modbus protocol and are compatible with mainstream PLC brands such as Siemens, Mitsubishi, Schneider, Delta, Omron, others.

Are there mixed digital and analog modules?

Available. We offer a variety of combination models, including digital only (DI/DO), analog only (AI/AO), and digital + analog combination models, to support flexible selection and expansion.

Does the module support customization?

Support. We have our own R&D team and factory, supporting IO point customization, communication protocol customization, structure size optimization, brand Logo customization and other OEM/ODM services.